Product Information

You are here:
Dental Technology » css - certified symbiotic system » Courses

Dental Technology

css - certified symbiotic system


From impression taking up to the tension-free,
precisely fitting prosthesis

(Product information: ► bredent-casting technique)

css is a certified system (in accordance with ISO 9001) for the production of precisely fitting dental prosthesis from impression taking all the way to integration.

Symbiotically (Greek „Symbiosis“ = Cohabitation, figuratively the cooperation) structured, it only functions if all parties work together for the mutual benefit, sensibly interacting like the cogs of a precision clockwork.


Side up

The System
The certified system consists of the:

1. Material symbiosis (PDF: ► Diagram [360 kb])
2. Standardization of work processes

Chemical and physically coordinated products (material symbiosis) are defined therein, and work processes (manuals „Optimized modeling, from impression taking to the one piece cast in combination technique“) are combined and standardized between dentist and dental technician in such a manner that precisely fitting, enduringly reproducible prosthesis are produced in an economic way.




These products are developed, manufactured and marketed by bredent in Senden, Germany under the highest quality requirements.

css is modularly structured, and continuously advanced and updated.



Side up

The Advantages

certified symbiotic system

  • increases the precise fit of your dental and laboratorial prosthetic works through coordinated system solutions
  • is immediately integratable as part of your existing or planned ISO certification
  • improves the utilization of our resources through simplification and visualization of work processes and reduces your valuable working time
  • increases the efficiency of your work through precise guidelines and optimal interconnection of laboratory and practice
  • enables you to work comfortably due to the logical system structure and increases your earnings by preventing repetitive work
  • provides security through comprehensible work steps and examination of procedures with integrated test modules
  • enhances as quality management system your professional competence towards patients and customers



Side up

Application Possibilities
certified symbiotic system css
exemplified by clinical cases



Side up

Dental practice: Impression taking
Fig. 1: breciform D - Perfekte Ergonomie
Wide handle plates facilitate working when taking impressions and result in enhanced precision to create the basis for successful prosthetic restorations.

“Ensuring simple, fast and precise use”

Information on ordering (bredent medical)
» Impression trays breciform D


Dental practice: Impression taking
Fig. 2: breciform D – the fast open impression

The position of the implants can be easily recognized and thus the tray can be easily, quickly and reliably customized.










Dental practice: Impression taking
Fig. 3: breciform D – convenient for the patient

Thanks to the perfectly designed tongue rest and rounded rims, stress to the patient can be eliminated to a high degree.










Dental practice: Impression taking
Fig. 4: breciform D – with occlusal stops for edentulous ridges

Sterilizable bar-shaped and triangular stops allow reliable and accurate impression taking also n edentulous ridges and prevents the impression from being "pressed through".

Information on ordering (bredent medical)
» breciform D, Occlusal-Stopps




Dental practice: Impression taking
Fig. 5: breciform D - breciform adhesive

breciform adhesive provides unsurpassed adaptation of the impression materials and ensures maximum precision.

Information on ordering (bredent medical)
» breciform adhesive





Dental practice: Impression taking
Fig. 6: brecision – impression material

brecision offers identical or better contraction values than a polyether impression material, combined with the advantages of an A silicone, e.g. easy demolding and pleasant taste.
No significant change in contraction after 2 hours.
„Source: Quintessence International 38 (2007), No. 1, Page 67 - 73“

The contraction of impression materials can be
determined with the KoEx measuring device.
Information on ordering
» KoEx Measuring Device




Dental practice: Impression taking
Fig. 7: brecision - Impression Materials


„Well readable details due to intense color contrast ...“

Information on ordering (bredent medical)
» brecision heavy body super-hydro
» brecision mono body super-hydro
» brecision light body super-hydro
» brecision regular body super-hydro





Side up

Dental Laboratory: Primary Construction
Fig. 1: Model Fabrication: Thixo-Rock

  • 0.06 % gypsum expansion after 2 hours
  • Maximum expansion after more than 48 hours < 0,08 %
  • Comparison stones further expand for up to 72 hours
Information on ordering
» Thixo-Rock (Stone Class IV) brown
» Thixo-Rock (Stone Class IV) ivory
» Thixo-Rock (Stone Class IV) grey
» KoEx Measuring Device



Labor: Primary construction
Fig. 2: Model Fabrication: Thixo-Rock

Clinical case of a model with Thixo-Rock

Information on ordering
» Multisil Mask: Multisil mask soft
» Dosing device








Laboratory: Primary construction
Fig. 3: Investing and Casting

The manual for users of the bredent casting technique.

Product information
» Symbiosis-modul: bredent-casting technique

Information on ordering
» Manual: bredent-casting technique






Laboratory: Primary construction
Fig. 4: Investing and Casting

Vacuum mixing system ecovac

» PDF: Optimal mixing process

Information on ordering
» ecovac: Mixing unit
» ecovac: Special mixing spiral
» ecovac: Mixing cups





Laboratory: Primary construction
Fig. 5: Investing and Casting

Slender design of bars is possible thanks to the one-piece casting technique.

Brevest Rapid 1 universal precision investment material:
  • For rapid preheating
  • For conventional preheating
Information on ordering
» Brevest Rapid 1


Laboratory: Primary construction
Fig. 6: Investing and Casting

1 = sprue, 2 = rinsing head and 3 = vent canals attached in accordance with the bredent casting technique.

Information on ordering
» bredent-casting technique: Spures
» bredent-casting technique: Rinsing Heads
» bredent-casting technique: Wax profiles






Laboratory: Primary construction
Fig. 7: Investing and Casting

Outstanding precision can be achieved using the one-piece casting technique

Information on ordering
» NEM-alloy Brealloy MK



Side up

Dental Laboratory: Duplication
Fig. 1: Investing and Casting

Measurements reveal that Exaktosil N15 shows a material contraction of 0.02 %, which is only half as much as that of comparable duplication silicones. Investment compound models turn out significantly more precise.

Information on ordering
» Exaktosil duplicating silicone



Laboratory: Duplicating
Fig. 2: Investing and Casting

Exaktosil N15 remains stable at 0.02 % after only 30 minutes, and precisely fitting investment compound models can be fabricated without loss of time. Other materials continue to contract for up to 24 hours.

"Measurements of the contraction of various silicone duplicating materials reveal considerable variations."

Information on ordering
» KoEx measuring unit



Laboratory: Duplicating
Fig. 3: Investing and Casting

The yellow color contrast facilitates for quick examination of any reproduction detail.

Information on ordering
» Duplicating silicone Exaktosil N15






Laboratory: Duplicating
Fig. 4: Investing and Casting

The yellow color contrast facilitates for quick examination of any reproduction detail.

Information on ordering
» Master-Copy duplicating System




Side up

Dental Laboratory: Secondary Construction
Fig. 1: Investment compound system
Directed expansion control of brevest M1 in various areas of an investment compound model through the investment compound liquids Bresol C+B and Bresol M, necessary for precisely fitting secondary constructions in the one-piece cast technique.

Bar with 85 % Bresol C+B investment compound liquid, remaining model with 70 % Bresol M investment compound liquid.

Information on ordering
» Bresol C+B
» Bresol M
» Brevest M1
» KoEx Measuring Device


» PDF: Optimal mixing process
Information on ordering » Mixing system ecovac

Laboratory: Secondary construction
Fig. 2: With 2 pivot latches src in one-piece cast technique

Completely modeled secondary construction, prepared for investing.

» Product information: bredent-casting technique
Information on ordering » Manual: bredent-casting technique





Laboratory: Secondary construction
Fig. 3: With 2 pivot latches src in one-piece cast technique

Lock blades and lock spindle are made of ceramic material and form as spacers during the casting process, precise surface fits for prefabricated titanium and stainless steel parts.








Laboratory: Secondary construction
Fig. 4: Sturdy, gracile and precisely fitting with brealloy MO.


brealloy MO:

  • biocompatible
  • corrosion resistant
  • DPH (Vickers) hardness of 380 (HV 10)
Information on ordering
» brealloy MO




Laboratory: Secondary construction
Fig. 5: Fitting the secondary construction on the patient













Laboratory: Secondary construction
Fig. 6: Complete incorporated prosthesis





Side up

Optimized Modelling
describes the fabrication procedure from impression taking to the completed prosthetic restoration in two parts. Using a flowchart, safe processing of the materials is illustrated and working times are reduced considerably. Work processes in the dental practice and laboratory are standardized.



Side up

Courses
bredent offers introductory courses and advanced level courses with a final test in the end. The courses for dental practices and dental laboratories are held separately. Impression taking and the proper fabrication of the models is demonstrated for the » practice. For the » laboratory, the course "Fabrication of a complex implant restoration" demonstrates the handling of the necessary materials and the principle of the material symbiosis.